694-1 I/O Interface SpecificationThe I/O terminal block and the I/O connector are available as the external control I/O interface of this product.• I/O terminal block: Loaded with the basic input/output to control the laser marker.• I/O connector: Loaded with the input/output for data configuration such as selecting a file number and the input/outputfor the specific functions.ンㄆㄇㄆㄓㄆㄏㄆ• Before using I/O, configure the system settings. Refer to “3-4-3 Settings before external control” (P.64).X1X2X3X4X5X6X7X8X9X10X11X12X13X14X15X16X17X18X19X20Y1Y2Y3Y4Y5Y6Y7Y8Y9Y10Y11Y12Y13Y14Y15Y16Y17Y18Y19Y20391 240Rear of controllerI/O terminal block I/O connector(Laser marker)HookThe I/O terminal block can beremoved by holding down thehooks. Connector specifications and modelsConnector position Connector specifications Model Manufacturer nameI/O terminalblockOn the lasermarker sideDedicated connector DMC1.5/20-GIF-3.5-LRP20THRPhoenix ContactCompanyUser side Accessories: DFMC1.5/20-ST-3.5-LRI/O Connector On the lasermarker sideMIL connector40-pin/maleXG4A-4034 OMRON CorporationUser side MIL connector40-pin/femaleRecommended item: XG4M-4030-T Wiring the shielded lineIf you use a shielded wire for the I/O terminal block and the I/O connector cable, you can use the frame ground terminal onthe rear of the controller as the frame earth of the shielded wire.Rear of controllerShielded wireFrame ground terminalME-LPGS-SM-8