1014-6-9 Count-up/count-down value correctionT1T5T3T4T2SELECT 0 - 2 IN (No.19-21)D0 - D7 IN (No.3-10)D8 - D15 IN (No.10-18)SET IN (No.2)SET OK OUT (No.28)TRIGGER IN (X5)READY OUT (Y5)*1*2*3PROCESSING OUT (Y10)ONOFFONOFFONOFFONOFFONOFFONOFFONOFFONOFFItem Time RemarksT1 0.5ms or more After a lapse of 0.5ms or more from specifying SELECT 0 IN to SELECT 2 IN and D0 IN toD15 IN, turn on SET IN (No.2).T2 0ms or more Keep the input until SET OK OUT (No.28) turns on.T3 2 to 510ms One-shot output. Set the output time on the system settings screen.There is a small margin of error for the setting value.T4 0ms or more Turn on TRIGGER IN (X5) after SET OK OUT (No.28) turns on.T5 2ms or more Keep the ON status for 2ms or more.*1 : Select the number input target with SELECT 0 IN to SELECT 2 IN as follows.Number input target SELECT 0 IN (No. 19) SELECT 1 IN (No. 20) SELECT 2 IN (No. 21)Count-up value correction OFF ON OFFCount-down value correction ON ON OFF*2 : Select a value from D0 to D7 for the counter number to correct the count-up/count-down value. The counter No. 0 to 3is assigned at D0 to D3 and the common counter No. 16 to 19 is assigned at D4 to D7 respectively.*3 : Specify a value in D8 to D15 for the step times of count-up or count-down in the binary system.ンㄆㄇㄆㄓㄆㄏㄆ• To specify the next counter value during the trigger processing, input SET IN (No.2) after PROCESSING OUT (Y10)turns ON.ME-LPGS-SM-8