1206-1-3 Connectionワㄐㄕㄊㄆ• To prevent damage of the image checker, do not install the camera in the laser emission area. Besides, take measuresto protect the camera against the reflected laser beam, such as installing a shutter in front of the camera lens. Connectable image checkerImage checkers compatible with this product are listed below.Usage Model Manufacturer namePosition correction PV230/PV200 Panasonic Devices SUNX Co, Ltd.Code checking PV230LP-ABR seriesDataMan series (Ethernet supported model) Cognex CorporationCharacter checking PV230 Panasonic Devices SUNX Co, Ltd.Image capturing and inspection PV230/PV200 Connection methodUse the Ethernet port on the laser marker controller and connect the image checker to link.This product can be connected with one device each for position correction and code reading.ンㄆㄇㄆㄓㄆㄏㄆ• For details of specifications and connection of the Ethernet port, refer to “5-3 Ethernet” (P.112). Connection exampleTo connect a position correction device (PV230), code reader (DataMan) and control PLC with the laser markerLaser markerDataMan(For code reading)PLC(For I/O control)PV230(For position correction)HUBExample of communication system settingsTo prevent duplication of IP addresses of network devices, set individual addresses.Laser marker PV230(For position correction)DataMan(For code reading)IP address 192.168.1.4 192.168.1.5 192.168.1.10Subnet mask 255.255.255.0Default gateway 192.168.1.1Port―Fixed value(Result output: 8601)(Command transmission: 8604)23 (Telnet)ンㄆㄇㄆㄓㄆㄏㄆ• Port on the laser marker side is a fixed value when PV230/PV200 is used.• Align the Port (command transmission) on the laser marker with DataMan's TelnetPort setting value when DataMan isused.• When the laser marker is connected an image checker one to one, no HUB is necessary.• The Ethernet port of this product is compatible with both straight cable and cross cable.ME-LPGS-SM-8