1044-6-12 Laser stop 1 inputIf LASER STOP 1 IN is released when laser is not radiating, the shutter is closed keeping the laser pumping on.If LASER STOP 1 IN is released when laser is radiating, the laser pumping is turned off, and the shutter is closed.Refer to “Laser marker operation when functions for safety measures are input” (P.77).T7T6T5T3T1T1T2T1 T1T4TRIGGER IN (X5)ALARM RESET IN (X15)LASER STOP 1 IN (X10)LASER STANDBY OUT (Y6)PROCESSING OUT (Y10)PROCESSING END OUT (Y11)PROCESSING FAIL OUT (Y12)WARNING OUT (Y14)ALARM OUT (Y15)SHUTTER OPEN 1 OUT (Y8)SHUTTER OPEN 2 OUT (Y9)SHUTTER ENABLE IN (X9)SHUTTER IN (X8)LASER SUPPLY IN (X6)READY OUT (Y5)ONOFFONOFFONOFFONOFFON (Close)OFF (Open)ONOFFON (Open)OFF (Close)ONOFFONOFFONOFFONOFFON (Normal)OFF (Error)ON (Normal)OFF (Error)MarkinginterruptionItem Time RemarksT1 Max. 1 sec. There is a delay time of around 200ms to max. 1 second from turning ON/OFF ofSHUTTER IN (X8) to turning ON/OFF of SHUTTER OPEN 1 OUT (Y8) and SHUTTEROPEN 2 OUT (Y9).SHUTTER OPEN 1 OUT and SHUTTER OPEN 2 OUT will be output by the sameoperation, but their output timing has a margin of error.T2 ― Total time for shutter opening and marking data creation. It varies depending on thequantity of the setting data.T3 2ms or more Keep the ON status for 2ms or more.T4 2 to 510ms This is One-shot output. Set the output time on the environment setting screen. There isa small margin of error for the setting value.T5 100ms or more Keep the ON status for 100ms or more.T6 Approx. 8 to 15 sec. Time for completion of laser pumping.• Normal: Approx. 8 sec.• Re-pumping right after turning the laser pumping off: Approx. 15 sec.T7 ― Total time for shutter opening and marking data creation, or time for laser pumping,whichever is longer.ME-LPGS-SM-8