77 Laser marker operation when functions for safety measures are inputIf INTERLOCK (X16, X17, X18, X19) or LASER STOP 2 IN (X11) is opened, regardless laser emission ON/OFF status, thelaser is powered OFF and the shutter is closed.The operation behavior of LASER STOP 1 IN (X10) varies depending on the laser emission ON/OFF status.Safety function Laser marker operation Release method RemarksINTERLOCK 1 (X16, X17)INTERLOCK 2 (X18, X19)• Laser Pumping: OFF• Internal Shutter: CLOSE• Status: Alarm E400, E401 *2Close bothINTERLOCK 1 andINTERLOCK 2connectionsrespectively and inputalarm reset.The power supply oflaser source is shutdown by the relayoperation (hardwarecontrol).LASER STOP 1 IN (X10, X11 *1) Opened during laser emission• Laser Pumping: OFF• Internal Shutter: CLOSE• Status: Alarm E402Close LASER STOP 1IN connection and inputalarm reset.The power supply oflaser source is shutdown through theinternal circuit by thesoftware control.Opened at non-emitting withopened shutter• Laser Pumping: Hold ON• Internal Shutter: CLOSE• Status: Warning E600Close LASER STOP 1IN connection.LASER STOP 2 IN (X11) *1 • Laser Pumping: OFF• Internal Shutter: CLOSE• Status: Alarm E403, E501 *2Close LASER STOP 2IN connection and inputalarm reset.*1 : For X11, you can select its behavior from LASER STOP 1 IN or LASER STOP 2 IN by the setting of LASER MARKERNAVI smart. (Initial setting: LASER STOP 2 IN)*2 : The error will not occur if the shutter is closed (laser is not radiating) with the PC configuration software controlenabled.ME-LPGS-SM-8