23Item ModelLP-GS051 LP-GS051-L LP-GS052Laser Marker NAVI smart displaylanguage English, German, Simplified Chinese, Traditional Chinese, Japanese, KoreanRequired time for system startup Approx. 10 secondsRequired time for laser pumping Approx. 8 seconds to Max. 15 secondsPower voltage 90V to 132V AC or 180V to 264V AC (including ±10% voltage fluctuations) *8Frequency: 50/60HzPowerconsumption(Consumptioncurrent) *9100V AC 370VA or less (4.2A or less)200V AC 500VA or less (2.8A or less)Grounding method Direct earth for both the head and the controllerCooling method Forced cooling for both the head and the controllerOperating ambient temperature *10 0°C to +40°CAmbient temperature for storage *10 -10°C to +60°COperating ambient humidity *10 35 to 85%RHOvervoltage category ⅡPollution degree 2Use location Indoor; at an altitude of 1000 m or belowInstallationdirectionHead In all directionsController Vertically or horizontallyWeight Head Approx. 11kgController Approx. 8.0kgBattery(mounted inproduct)Type Manganese dioxide lithium primary batteryModel AFPX-BATT (CR-2450)Quantity 1 pieceWeight Approx. 7.0g*1: Average output power from the laser marker at delivery time with the maximum laser power setting.*2: The work distance base position has approx. +/-0.5mm deviation per product.*3: The value shown here is the configuration range that can be input. The setting values that can keep the quality ofmarking or processing vary depending on the setting details and the target materials.*4: VEC is a graphic file format dedicated for the laser marker. To use AI or EPS files, convert them to VEC format with theattached software “ExportVEC”.*5: Some of the languages or character types are not supported by this laser marker. Characters written from right to leftsuch as Arabic or Hebrew, characters based on ligature such as Indian languages cannot be input.*6: OS versions of which Microsoft has ended support are excluded.*7: The Bluetooth function is not available with the models ending with “-F”. For the Bluetooth specifications, refer to“Connection type” (P.45).*8: The power supply voltage switches automatically.*9: The typical value of the inrush current at startup is as follows: (Duration time is 10ms or less.)At 100V AC: 60AAt 200V AC: 120A*10: Common to the controller and the head. No condensation or freezing shall be allowed. If there is a gap between thestored temperature and operating temperature, make sure to have the product get used to the operating ambienttemperature gradually prior to use to prevent the dew condensation.ME-LPGS-SM-8