1523. Connect the laser marker and Laser Marker NAVI smart online, and select “Maintenance” from thescreen selection menu.4. Click the “Laser pumping ON/OFF” of the “Laser MarkerOperation” tool to pump laser.5. Click “Laser radiation for measurement” of the “Laser MarkerOperation” tool.6. Enter the laser power and other lasersettings, then click “Laser radiation”.Click “Yes” in the laser radiation confirmationdialog to irradiate the laser.ンㄆㄇㄆㄓㄆㄏㄆ• For LP-GS051(-L) type, use “work distance” indicationof the guide laser to confirm the setting position of thepower meter detector.Set the detector so that the cross indication is on thecenter of the detector. (Do not set it to the positionwhere the dot indication emitted in oblique overlaps thedetector.)• For stable measurement results, it is recommended to obtain the average output value by measuring the output afterabout 30 seconds from the start of laser radiation for 10 to 30 seconds.• The settings of laser radiation for measurement are common in all files.WARNING • Be sure to wear protective goggles.• During the radiation, the laser energy is concentrated to one point. Use duecaution with long period radiation, it may cause a fire or damage to the object.7. Click “Stop” to stop laser radiation.The laser radiation for measurement will automaticallystop after about one minute even without clicking“Stop”.ME-LPGS-SM-8