3-8 BOP HIPWR 111315apply only to local operation. When in remote, only the main password is accessible, actingas a general password (see PAR B.140). The functions that can be password protected areInterface settings, Max/Min settings, Load type, Test, Calibration, Power-up Settings, and Key-pad lockout at power-up (see Figure 3-5 for factory default password settings). In addition, it ispossible to prevent changes made to the display settings from being saved for power up by set-ting Save Display Chg to Disable.When the unit is operating in remote mode with Keypad @ local activated, a password isrequired before the unit can be returned to local operation. In addition, when a waveform is exe-cuting in local mode, depressing % to stop the waveform requires a password before thewaveform is stopped.To change any password you must enter the Admin 2 password to access the Password Menu.The unit is shipped with the Admin 2 password set to “KEPCO,” the Main Unit password set to”DEFAULT,” and the Admin 1 password is not assigned. To change the password or to protectone of the protected menus, proceed as follows:1. Press % from the power-up screen to enter the General Setup menu. Highlight Passwordand press !.2. Enter the Admin 2 password (see PAR. 3.2.4.3 for details), then press ! to verify. ThePassword Protection menu (see Figure 3-5) is now displayed.3. To change a password, highlight the Main Unit, Admin 1 or Admin 2 password and press !to modify.4. Press CLEAR to erase the previous password from memory.5. Enter the new password (see PAR. 3.2.4.3) and press $ to save. Up to eight charactersare permitted for passwords.NOTE: Do NOT use space characters for passwords6. To protect or unprotect a menu highlight the password setting for the menu (Interface, Max-Min, Load, Test, Power-up, Keyboard @ Local, Keypad@power-up) and press ! to modify.Highlight either the desired password (Main Unit, Admin 1 or Admin 2) or Unprotected andpress $ to save.NOTE: To restore the password protection defaults shown in Figure 3-5, press @; this leavesthe three individual passwords remain unchanged.7. When complete, press $ to save for power-up or % to apply the changes (without savingfor power-up) and exit.3.2.4.3 HOW TO ACCESS A PASSWORD PROTECTED MENUAn administrator can independently assign one of three passwords (Main Unit, Admin 1 orAdmin 2) to eight functions. Under General Setup the Series/Parallel submenu is assigned theAdmin 2 password; this cannot be changed.When trying to modify a protected setting or access a protected menu, the message PASS-WORD IS REQUIRED appears at the top, and the first character is highlighted. Proceed as fol-lows: