B-12 BOP-1K 111315B.38 [SOURce:]CURRent[:LEVel]:PROTect:LIMit[:BOTH]? QUERYCURR:PROT:LIM:[:BOTH]?Syntax: Short Form: [SOUR:]CURR[:LEV]:PROT:LIM[:BOTH]?Long Form: [SOURce:]CURRent[:LEVel]:PROTect:LIMit[:BOTH]?Returns ,Description: Identifies the maximum value possible for protection limits for current (positive, negative); maximum is1% greater than rated output current.B.39 [SOURce:]CURRent[:LEVel]:PROTect:LIMit:NEGative COMMANDCURR:PROT:LIM:NEGSyntax: Short Form: [SOUR:]CURR[:LEV]:PROT:LIM:NEG Long Form: [SOURce:]CURRent[:LEVel]:PROTect:LIMit:NEGative where is between minimum (box) value (Figure 1-3) and 1% above rated (nominal) outputcurrent.Description: Establishes the minimum (maximum absolute) value possible for the negative protection limit for cur-rent. This may be set up to 1% greater than rated current. Requires MEM:UPD (PAR. B.12) to save forpower up. See PAR. 3.5.2.2 and Figure 3-16 for special programming considerations.B.40 [SOURce:]CURRent[:LEVel]:PROTect:LIMit:NEGative? QUERYCURR:PROT:LIM:NEG?Syntax: Short Form: [SOUR:]CURR[:LEV]:PROT:LIM:NEG?Long Form: [SOURce:]CURRent[:LEVel]:PROTect:LIMit:NEGative?Returns: Description: Identifies the minimum (maximum absolute) value possible for the negative protection limit for current.B.41 [SOURce:]CURRent[:LEVel]:PROTect:LIMit:POSitive COMMANDCURR:PROT:LIM:POSSyntax: Short Form: [SOUR:]CURR[:LEV]:PROT:LIM:POS Long Form: [SOURce:]CURRent[:LEVel]:PROTect:LIMit:POSitive where is between minimum (box) value (Figure 1-3) and 1% above rated (nominal) outputcurrent.Description: Establishes the maximum value possible for the positive protection limit for current. This may be setup to 1% greater than rated current. Requires MEM:UPD (PAR. B.12) to save for power up. See PAR.3.5.2.2 and Figure 3-16 for special programming considerations.B.42 [SOURce:]CURRent[:LEVel]:PROTect:LIMit:POSitive? QUERYCURR:PROT:LIM:POS?Syntax: Short Form: [SOUR:]CURR[:LEV]:PROT:LIM:POS?Long Form: [SOURce:]CURRent[:LEVel]:PROTect:LIMit:POSitive?Returns: Description:Identifies the maximum value possible for the positive protection limit for current.B.43 [SOURce:]CURRent[:LEVel]:TRIGgered[:AMPlitude] COMMAND CURR:TRIGSyntax: Short Form: [SOUR:]CURR[:LEV]:TRIG[:AMP] Long Form: [SOURce:]CURRent[:LEVel]:TRIGgered[:AMPlitude] = digits with decimal point and Exponent, e.g., 2.71E1 for 27.1Description: Programs current value to be transferred to output by *TRG (trigger) commands. This commandcan be used to reset many power supplies to preselected parameters by issuing a single *TRG com-mand. Actual output current will depend on load conditions. If the value exceeds the maximum for themodel being programmed, error message -222,”Data out of range” is posted in output queue. RelatedCommands: CURR, *TRG, TRIG