BOP-1K 111315 B-13B.44 [SOURce:]CURRent[:LEVel]:TRIGgered[:AMPlitude]? QUERY CURR:TRIG?Syntax: Short Form: [SOUR:]CURR[:LEV]:TRIG[:AMP]?Long Form: [SOURce:]CURRent[:LEVel]:TRIGgered[:AMPlitude]?Return Value: = digits with decimal point and Exponent, e.g., 2.71E1 for 27.1Description: Returns the current value established by CURR:TRIG command.B.45 [SOURce:]FUNCtion:MODE COMMAND FUNC:MODESyntax: Short Form: FUNC:MODE {VOLT | CURR | EXT}Long Form: [SOURce:]FUNCtion:MODE {VOLT | CURR | EXTernal}Description: Establishes the operating mode of the power supply. VOLT = Constant Voltage mode (CV). CURR= Constant Current mode (CC). EXT = External. FUNC:MODE VOLT commands power supply to Volt-age mode, FUNC:MODE CURR commands power supply to Current mode. Commanded mode estab-lishes parameters (voltage or current) monitored for error conditions. Actual mode depends upon loadconditions. When commanded to Voltage mode, if load conditions cause the power supply to try toexceed the current limit, the unit will flag an error condition. When commanded to Current mode, ifload conditions cause the power supply to try to exceed the voltage limit, the unit will flag an error con-dition.B.46 [SOURce:]FUNCtion:MODE? QUERY FUNC:MODE?Syntax: Short Form: FUNC:MODE? Long Form: [SOURce:]FUNCtion:MODE?Return value: 0 (voltage mode) or 1 (current mode)Description: Returns the operating mode of the power supply. 0 = Constant Voltage mode (CV). 1 = ConstantCurrent mode (CC).B.47 [SOURce:]FUNCtion:MODE:TRIGger COMMAND FUNC:MODE:TRIGSyntax: Short Form: FUNC:MODE:TRIG {VOLT | CURR}Long Form: [SOURce:]FUNCtion:MODE:TRIGger {VOLT | CURR}Description: Establishes the operating mode of the power supply when a TRIGger command is sent. VOLT =Constant Voltage mode (CV). CURR = Constant Current mode (CC). FUNC:MODE:TRIG VOLT com-mands power supply to Voltage mode when a TRIGger command is sent, FUNC:MODE:TRIG CURRcommands power supply to Current mode when a TRIGger command is sent.B.48 [SOURce:]FUNCtion:MODE:TRIGger? QUERY FUNC:MODE:TRIG?Syntax: Short Form: FUNC:MODE:TRIG? Long Form: [SOURce:]FUNCtion:MODE:TRIGger?Return value: 0 = voltage mode or 1 = current modeDescription: Returns the operating mode which the power supply will enter when a trigger command issent. VOLT = Constant Voltage mode (CV). CURR = Constant Current mode (CC).B.49 [SOURce:]LIST:CLEar COMMAND LIST:CLESyntax: Short Form: LIST:CLE Long Form: LIST:CLEar>Description: Clears all list entries by setting all pointers to 0. Releases control of the Output Off flag at EXTPROTECT PORT, pins 5 and 6 (see Table 2-4), from the programmed list. Related Commands: AllLIST commands (See example, Figure B-5.)