3-4 BOP HIPWR 111315FIGURE 3-3. POWER-UP SCREEN SHOWING GRAPHIC METERSFIGURE 3-4. POWER-UP SCREEN SHOWING TIME LINE GRAPHWhen in Voltage mode, the power supply will (within the configured and rated limits) provide theprogrammed output voltage. Current is determined by the load, and cannot exceed the CurrentProtect limits. Mode displayed at the upper right is VOLTAGE SOURCE. If the protect limit isreached, CPROTECT is displayed.When in Current mode, the power supply will (within the configured and rated limits) provide theprogrammed output current. Voltage is determined by the load, and cannot exceed the VoltageProtect limits. Mode displayed at the upper right is CURRENT SOURCE. If the protect limit isreached, VPROTECT is displayed.If CPROTECT (current protection), VPROTECT (voltage protection) or PROTECT (analog pro-tection, either voltage or current) is displayed, the power supply output is controlled by the pro-tect channel and will not exceed the preprogrammed protection limit.When in Source mode, the power supply is delivering (sourcing) energy to a passive load.VOLTAGE00000.VOLTAGE00000.