BOP HIPWR 111315 2-72. With no load connected, set POWER switch to the ON position. Each time the unit is turnedon an internal self-test is performed. The alphanumeric display (LCD) shows the processorfirmware revision history and lists various tests performed during the internal self-test. Aseach test is completed, PASS or FAIL is displayed. If all tests pass, the unit goes into thedefault mode. If a failure occurs, the failure is displayed. Figure 3-3 shows the factory config-ured power on defaults displayed on the LCD.3. Connect a digital voltmeter (DVM) (resolution and accuracy of 0.01% or better) to theOUTPS and COMS terminals at the rear panel terminal block.4. Use the keypad to enter the rated maximum voltage of the power supply (e.g., enter 36 for amodel BOP 36-28MG) and press ENTER. If STANDBY indicator is lit, press STANDBY key.5. Verify DVM voltage reading agrees with programmed voltage within 0.03% of rated maxi-mum voltage and agrees with displayed voltage on LCD within 0.05% of rated maximumvoltage.TABLE 2-11. IEEE 488 PORT INPUT/OUTPUT PIN ASSIGNMENTSCONNECTOR PIN SIGNAL NAME FUNCTIONIEEE 488PORTJ51 DI01 I/O Line2 DI02 I/O Line3 DI03 I/O Line4 DI04 I/O Line5 EOI End or Identify6 DAV Data Valid7 NRFD Not Ready for Data8 NDAC Not Data Accepted9 IFC Interface Clear10 SRQ Service Request11 ATN Attention12 SHIELD Shield13 DI05 I/O Line14 DI06 I/O Line15 DI07 I/O Line16 DI08 I/O Line17 REN Remote Enable18 GND Ground (signal common)19 GND Ground (signal common)20 GND Ground (signal common)21 GND Ground (signal common)22 GND Ground (signal common)23 GND Ground (signal common)24 LOGIC GND Logic Ground