Chapter 1515-315.2 Error Code Details15.2.1 List of Error Codes 0012-0886imagePRESS C1 P / imagePRESS C1 / imagePRESS C1+ (Printer) / imagePRESS C1+T-15-2Code Cause (Detection Description) RemedyE000 At power on, the rise in the temperature of the fixing assembly is not high enough.There is an open circuit or poor contact in the following: main thermistor (THM1, THM3, THM5), sub thermistor (TP1, TP2, TP3), or heater (H1, H2,H3, H4). The AC driver PCB or DC controller is faulty.0001 During warm-up, the temperature does not rise after the specifiedperiod of time (300 sec)Reset in service mode: COPIER>FUNCTION>CLEAR>ERR0002 During warm-up, the temperature does not rise after the specifiedperiod of time (after reaching warm-up 1, 360 sec)Reset in service mode: COPIER>FUNCTION>CLEAR>ERR0003 During warm-up, the temperature does not rise after the specifiedperiod of time (after reaching warm-up 2, 300 sec)Reset in service mode: COPIER>FUNCTION>CLEAR>ERR0004 During warm-up, the temperature does not rise after the specifiedperiod of time (after reaching warm-up 3, 360 sec)Reset in service mode: COPIER>FUNCTION>CLEAR>ERR0005 During warm-up after the fixing assembly jam, the temperaturedoes not rise after the specified period of time (600 sec)Reset in service mode: COPIER>FUNCTION>CLEAR>ERRE001 The rise in temperature of the fixing assembly is excessive.There is an open circuit or poor contact in the following: main thermistor (THM1, THM3, THM5), sub thermistor (THM4, THM5, THM6), or heater(H1, H2, H3, H4). The AC driver PCB or the DC controller PCB is faulty.0001 The rise in the temperature of the fixing roller is excessive(hardware detection)Reset in service mode: COPIER>FUNCTION>CLEAR>ERR0002 The rise in the temperature of the external heat roller is excessive(hardware detection)Reset in service mode: COPIER>FUNCTION>CLEAR>ERR0003 The rise in temperature of the inlet roller is excessive (hardwaredetection)Reset in service mode: COPIER>FUNCTION>CLEAR>ERR0004 The rise in temperature of the edge of the external heat roller isexcessive (hardware detection)Reset in service mode: COPIER>FUNCTION>CLEAR>ERR0005 The rise in temperature of the edge of the inlet roller is excessive(hardware detection)Reset in service mode: COPIER>FUNCTION>CLEAR>ERR0011 The rise in temperature of the fixing roller is excessive .The fixing main thermistor is 200 deg C or more, and its statecontinues for 500 msec.Reset in service mode: COPIER>FUNCTION>CLEAR>ERRE002 There is an open circuit or poor contact in the following: main thermistor (THM1, THM3, THM5), thermal switch (TP1, TP2, TP3), or heater (H1, H2,H3, H4). The AC driver PCB or DC controller is faulty.0010 The temperature of the fixing roller reaches 80 deg C, but drops 50deg C or less for 1 sec..Reset in service mode: COPIER>FUNCTION>CLEAR>ERR0020 The temperature of the external heat roller reaches 80 deg C, butdrops 50 deg C or less for 1 sec.Reset in service mode: COPIER>FUNCTION>CLEAR>ERR0030 The temperature of the inlet roller reaches 80 deg C, but drops 50deg C or less for 1 sec.Reset in service mode: COPIER>FUNCTION>CLEAR>ERRE003 After standby, the drop in temperature of the fixing assembly is excessive.There is an open circuit or poor contact in the following: main thermistor (THM1, THM3, THM5), thermal switch (TP1, TP2, TP3), or heater (H1, H2,H3, H4). The AC driver PCB or DC controller is faulty.0041 During standby, the drop in the temperature of the fixing roller isexcessive: (detecting temperature of the main thermistor or the subthermistor)During standby, the temperature of the fixing roller is 130 deg Cor less for 1 secReset in service mode: COPIER>FUNCTION>CLEAR>ERR0042 During standby, the drop in the temperature of the external heatroller is excessive: (detecting temperature of the main thermistoror the sub thermistor)During standby, the temperature of the external heat roller is 160deg C or less for 1 secReset in service mode: COPIER>FUNCTION>CLEAR>ERR0043 During standby, the drop in the temperature of the inlet roller isexcessive: (detecting temperature of the main thermistor or the subthermistor)During standby, the temperature of the inlet roller is 60 deg C orless for 1 secReset in service mode: COPIER>FUNCTION>CLEAR>ERR0051 During black/white printing, the drop in the temperature of thefixing roller is excessive: (detecting temperature of the mainthermistor or the sub thermistor)During black/white printing, the temperature of the fixing roller is100 deg C or less for 1 secReset in service mode: COPIER>FUNCTION>CLEAR>ERR0052 During black/white printing, the drop in the temperature of theexternal heat roller is excessive: (detecting temperature of themain thermistor or the sub thermistor)During black/white printing, the temperature of the external heatroller is 150 deg C or less for 1 secReset in service mode: COPIER>FUNCTION>CLEAR>ERR0053 During black/white printing, the drop in the temperature of theinlet roller is excessive: (detecting temperature of the mainthermistor or the sub thermistor)During black/white printing, the temperature of the inlet roller is60 deg C or less for 1 secReset in service mode: COPIER>FUNCTION>CLEAR>ERR