Chapter 1212-812.3 Scheduled Servicing Basic Procedure12.3.1 General Procedure for Scheduled Servicing 0012-1982imagePRESS C1 P / imagePRESS C1 / imagePRESS C1+ (Printer) / imagePRESS C1+- The scheduled servicing should be basically implemented per 25,000 sheets.- Check the service book when going for the scheduled servicing. Bring it when the parts replacement may be necessary.- Connecting the power plug for a long time at the place filled with the dust, moisture and oily smoke may cause a fire (The dust accumulated around thereabsorbs the moisture and may cause the poor insulation). The power plug should be regularly unconnected, the dust or dirt accumulated around it/the consentshould be cleaned with a dry cloth.1.Operation Procedure1) Greetings to the person in charge: The status confirmation2) The counter record: Check the misprint3) Check the following items, clean/adjust each area.4) Checking the Waste Toner ReceptacleWhen the waste toner accumulates above the level of half of the receptacle, collect the waste toner in a vinyl bag, etc. Or replace the waste toner receptacle- When disposing the waste toner, obey the disposal standards of each local government.- Do not throw the waste toner into the fire (It may explode, very dangerous!)5) Clean the copyboard glass and reading glass6) Implement the test copy.7) Implement the sample copy.8) Operation check for the leakage breakerPress the test switch of the leakage breaker at the status of power switch (ON), and check if the leakage breaker normally works (The breaker switch tilts on theside of OFF to shut the power).If the leakage breaker does not normally work, replace the leakage breaker and check it again.2. Recovery ProcedureAfter checking the operation, turn OFF/ON the main power switch.1) Organize the sample copies, clean and clear up the surroundings of the machine.2) Record the last counter. Record also the service counter for COUNTER>DRBL-1 'FX-UP-RL'.3) Write them in the service book, report them to the person in charge. Write the history of the leakage breaker operation check in the service book.12.3.2 Scheduled Servicing List Reader Unit 0014-2820imagePRESS C1 P / imagePRESS C1 / imagePRESS C1+ (Printer) / imagePRESS C1+Do not use the solvent/oil other than the specified one.MEMO:The meanings of marks used in the subsequent chart are as follows.A: Cleaning B: Replacement C: Lubrication D: Adjustment E: MaintenanceCheck itemsTest copy Image density standardsSoiled backgroundCharacter definitionMarginFixing Faulty registration, soiled backMargin specification(one-sided print)Leading edge: 4.0+1.5/-1.0mmLeft edge: 2.5+/-1.5mm(two-sided print) Leading edge: 4.0+1.5/-1.0mmLeft edge: 2.5+/-2.0mmFeeding system Registration upper lower rollerPaper powder at the front of theregistration assembly