Chapter 1616-2942. NETWORKT-16-2181) Turn off the main power switch.2) Connect the network cable to this machine and turn on the main power switch.3) Inform the system administrator of a user that installation of the main unit has been completed, and ask him/her to make network settings.4) Inform the system administrator of a user that the network connection is going to be checked, and check the remote host address (IP address of a PC terminal inthe user network) to send PING.5) Select a service mode item (COPIER>TEST>NETWORK>PING), enter the IP address checked in Procedure 4 using numeric keys in the control panel, pressthe OK key, and press the Start key.- When the connection is made to the network successfully, OK is displayed. (Procedure is completed.)- When NG is displayed, first check the connection status of the network cable. If the connection is made normally, go to Procedure 6 shown below. If there isa problem in the connection, connect the cable again and perform Procedure 5.6) Select a service mode item (COPIER>TEST>NETWORK>PING), enter the loopback address * (127.0.0.1), press the OK key, and press the Start key.- When NG is displayed, there is a problem in the TCP/IP setting for the machine. Go back to Procedure 3 and check the setting again.- When OK is displayed, there seems no problem in the TCP/IP setting for the machine. However, there may be a problem in the connection of the networkinterface board (NIC) or in the NIC itself, so check the connection in Procedure 7.* Since the signal of a loopback address returns before reaching the NIC, it can check the TCP/IP setting of the machine.7) Select a service mode item (COPIER>TEST>NETWORK>PING), enter a local host accress (IP address of the machine), and press the OK key.- When NG is displayed, there may be a problem in the connection with NIC or in NIC itself, so check the connection or replace the NIC.- When OK is displayed, there seems no problem in the network setting of the machine and the NIC. In this case, there may be a problem in the networkenvironment of the user, so contact the system administrator and ask him/her to take measures.F-16-322-SIDE Set an output mode for test print.1Setting value0: Single sided1: Double sided[Factory setting value / Value after RAM clear: 0]PG-QTY Set an output mode for test print.1Number of pages for test print: 1 to 999[Factory setting value / Value after RAM clear: 1]DENS-L Setting of the L color density for test printing (TYPE=5)Setting value: 0 to 255 1COLOR-L Switch the L color output for each test pattern (PG TYPE).When setting this item to "1" and other items to "0", single clear color is output.Setting value: 0, 1Standard value: 01COPIER > TEST > NETWORKSubheading Contents LevelPING Check the connection between this machine and network (only for TCP/IP).This mode is used to check the network connection at installation or to check a problem in thenetwork connection.1BML-DISP Set a screen displayed for BMlinks.Set whether or not to only display a device configuration screen without displaying a jobcondition/history in the system status screen.2Setting value0: Display a normal system status screen.1: Display a device configuration screen only.[Factory setting value / Value after RAM clear: 0]COPIER > TEST > PGSubheading Contents LevelCounterOptionFunctionI/ONETWORK READY< > < >+/- OKDisplay AdjustResult (OK/NG)PINGIP address input0 . 0Test