B7 SYSTEM ADMINISTRATION—HARDWARE SETTINGS346 Installation ManualB7.2 Port SettingPort Setting MenuNoteThe maximum number of ports depends on the VPS model.To access the menu for Port Setting, follow the menu path as shown:System Administration Top Menu-1-6-2To access the menu Port Setting Menu for the selected port, follow the menu pathas shown:System Administration Top Menu-1-6-2-Port No.(1-24)Table B-41Parameter Value Range(Default)Description/FunctionFlash Time 1. 100 ms2. 300 ms3. 600 ms4. 900 ms(600)Specifies the length of time the hook switch must bepressed before the PBX will recognize it as a flash hooksignal. See the PBX manual to determine the correctvalue.CPC Signal 1. None2. 6.5 ms3. 150 ms4. 300 ms5. 450 ms6. 600 ms(None)Specifies the minimum time necessary to detect aninterruption in the CPC (Calling Party Control) signalreceived from the PBX. The VPS is able to determinethat the line has been disconnected when it detects aninterruption of the CPC signal.DisconnectTime1-8 s(2)Specifies the length of time the line will temporarily beunavailable after a call has ended.Dial Mode 1. DTMF2. Pulse 10 pps3. Pulse 20 pps(DTMF)Specifies the dial mode for DTMF (touchtone) or Pulse.If Pulse is specified, pulse speed (10/20 pps) must beselected.NoteThis setting only affects outward dialing from theVPS. The VPS can only receive DTMF (touchtone)signals.