7.2 UTILITY COMMANDS208 Installation Manual7.2.6 Error Log Display (ELOG)Use the ELOG command to diagnose VPS problems. Selection of this command will displayan error log.Type ELOG, then Press RETURN.NoteThe following tables display and explain the errors that the system can identify.* = Port number (KX-TVS125: 1-6; KX-TVS225: 1-12; KX-TVS325: 1-24)Table 7-2 Device Error Log IndicationsIndication MeaningCPU MEM-GET CPU board software memory acquisition error.CPU board is short of memory temporarilybecause of too much traffic.CLOCK Clock access error. Clock IC is out of order.Check the hardware.DISK DATA R/W (xx:yyyy) HDD access error. If there is a sector that oftencauses errors, check the disk.xx : IDE error codeyyyy : read/write error sector numberDSP* SCAN DSP-SCAN error. DSP is out of order. Check thehardware.DSP* FIFO DSP/FIFO error. During the system is handlingcalls, there is something wrong with DSP and FIFOmemory temporarily.CPU APPLICATION (x) Application error. While the system is handlingcalls, temporary application error occurs.x: port numberCOM. Communication error between CPU and DSPDATA Process error of voice dataMEM. Memory errorPRG. Program error in CPU cardR/W Read/Write error of Hard Disk$ ELOGDEVICE ERROR TIMEJUL-14 2:00 PMMEM-GET1. CPUJUL-14 2:00 PM2. CLOCKJUL-14 2:00 PMDATA R/W (xx:yyyy)3. DISKJUL-14 2:00 PMSCAN4. DSP*JUL-14 2:00 PMFIFO5. DSP*JUL-14 2:00 PMAPPLICATION (x)6. CPU* = Port number (KX-TVS125: 1-6; KX-TVS225: 1-12; KX-TVS325: 1-24)