7.7 Data lists7.7.1 Machine data7.7.1.1 Displaying machine dataNumber Identifier: $MM_ Description9004 DISPLAY_RESOLUTION Display resolution9010 SPIND_DISPLAY_RESOLUTION Display resolution for spindles9011 DISPLAY_RESOLUTION_INCH Display resolution for INCH system of measurement7.7.1.2 NC-specific machine dataNumber Identifier: $MN_ Description10000 AXCONF_MACHAX_NAME_TAB Machine axis name10050 SYSCLOCK_CYCLE_TIME System basic cycle10070 IPO_SYSCLOCK_TIME_RATIO Factor for interpolator cycle10060 POSCTRL_SYSCLOCK_TIME_RATIO Factor for position-control cycle10200 INT_INCR_PER_MM Computational resolution for linear positions10210 INT_INCR_PER_DEG Computational resolution for angular positions10220 SCALING_USER_DEF_MASK Activation of scaling factors10230 SCALING_FACTORS_USER_DEF Scaling factors of physical quantities10240 SCALING_SYSTEM_IS_METRIC Basic system metric10250 SCALING_VALUE_INCH Conversion factor for switchover toinch system10260 CONVERT_SCALING_SYSTEM Basic system switchover active10270 POS_TAB_SCALING_SYSTEM Measuring system of position tables10290 CC_TDA_PARAM_UNIT Physical units of the tool data for CC10292 CC_TOA_PARAM_UNIT Physical units of the tool edge data for CC13050 DRIVE_LOGIC_ADDRESS Logical drive addresses13060 DRIVE_TELEGRAM_TYPE Standard message frame type for PROFIBUS DP13070 DRIVE_FUNCTION_MASK DP function used13080 DRIVE_TYPE_DP Drive type PROFIBUS DP7.7.1.3 Channelspecific machine dataNumber Identifier: $MC_ Description20150 GCODE_RESET_VALUES Initial setting of the G groupsG2: Velocities, setpoint / actual value systems, closed-loop control7.7 Data listsBasic Functions374 Function Manual, 01/2015, 6FC5397-0BP40-5BA2