87EnglishError responseError messageLastterminalsymbol“ERR1” : Undefined controlcommand(CR)0x0d“ERR2” : Out of parameter range“ERR3” : Busy status or receptioninvalid period“ERR4” : Timeout or receptioninvalid period“ERR5” : Wrong data length“PDPCONTROLERRA”: Mismatching ofpassword4 bytes or 15 bytes 1 byte■ When the WEB control administratorprivileges password has not been set (Non-protect mode)Connection method1 Obtain the display’s IP address and the port number(Default is 1024), and request connection to thedisplay.The IP address and the port number can be obtainedfrom the following menus.• IP address:[Setup] → [Network settings] → [LAN setup] or[Network status]• Port number:[Setup] → [Network settings] → [LAN setup]● For more detail of the settings, see page 72.2 The display responds.Response dataData part Space ModeLastterminalsymbol[PDPCONTROL](ASCIIcharacterstring)[ ]0x20[0]0x30(CR)0x0d10 bytes 1 byte 1 byte 1 byteMode:0 = Non-protect modeCommand transmission methodTransmit in the following command formatTransmitted dataControlsymbol Data part ControlsymbolLastterminalsymbol(STX)0x02Controlcommand(ASCIIcharacterstring)(ETX)0x03(CR)0x0d1 byte Undefined 1 byte 1 byteReceived dataControlsymbol Data part ControlsymbolLastterminalsymbol(STX)0x02Controlcommand(ASCIIcharacterstring)(ETX)0x03(CR)0x0d1 byte Undefined 1 byte 1 byteError responseError messageLastterminalsymbol“ERR1” : Undefined controlcommand(CR)0x0d“ERR2” : Out of parameterrange“ERR3” : Busy status orreception invalidperiod“ERR4” : Timeout or receptioninvalid period“ERR5” : Wrong data length4 bytes 1 byte