2 Parameters2.2 List of parametersSINAMICS G130/G150652 List Manual (LH2), 04/2014, A5E03263479ADescription: Displays the encoder status according to PROFIdrive for a squarewave encoder.Index: [0] = Encoder 1[1] = Encoder 2[2] = Encoder 3Note: After alarm A3x422 is output, this parameter is set for 100 ms.Description: Sets the component number for the SMI/DQI for which motor and/or encoder data should be saved, deleted ordownloaded.Dependency: Refer to: p4691, p4692, p4693Note: DQI: DRIVE-CLiQ Sensor IntegratedSMI: SINAMICS Sensor Module IntegratedDescription: Setting for the saving/downloading/deletion of motor and/or encoder data for the component specified in p4690(SMI/DQI).A backup of this data can be saved to non-volatile memory. The backup procedure is performed automatically as partof the function for saving to non-volatile memory (p0977 = 1 or "Copy RAM to ROM"). If a part is replaced, the saveddata can be reloaded.Procedure:p4690 = set component numberp4691 = 1, 2, 30: Set the required procedure (save/download/delete).p4691 = 9, 10, 36: Feedback signal on successful completion of the procedure.p4691 = 11... 22, 37, 38: Error values if the procedure could not be executed successfully.Value: 0: Inactive1: Save SMI data2: Download SMI data9: SMI data downloaded and POWER ON required for component10: SMI data backup complete11: SMI data backup for selected component not found12: Selected component not available or not connected13: Insufficient memory space for backup14: Format of saved data is incompatible15: Transfer fault during data download16: Transfer fault during data backup17: Data backup does not match parameterized encoder/motorr4689[0...2] CO: Squarewave encoder diagnostics / Sq-wave enc diagVECTOR_G Can be changed: - Calculated: - Access level: 4Data type: Unsigned32 Dyn. index: - Func. diagram: -P-Group: Encoder Units group: - Unit selection: -Not for motor type: - Scaling: - Expert list: 1Min Max Factory setting- - -p4690 SMI spare part component number / SMI comp_noCU_G130_DP,CU_G130_PN,CU_G150_DP,CU_G150_PNCan be changed: T Calculated: - Access level: 1Data type: Unsigned16 Dyn. index: - Func. diagram: -P-Group: Displays, signals Units group: - Unit selection: -Not for motor type: - Scaling: - Expert list: 1Min Max Factory setting0 399 0p4691 SMI spare part save/download data / Save/DL SMI dataCU_G130_DP,CU_G130_PN,CU_G150_DP,CU_G150_PNCan be changed: T Calculated: - Access level: 1Data type: Integer16 Dyn. index: - Func. diagram: -P-Group: Displays, signals Units group: - Unit selection: -Not for motor type: - Scaling: - Expert list: 1Min Max Factory setting0 39 0