2 Parameters2.2 List of parametersSINAMICS G130/G150146 List Manual (LH2), 04/2014, A5E03263479ADescription: Displays the stator leakage time constant.Note: The value is calculated from the total of all leakage inductances (p0233*, p0353, p0356, p0358) divided by the total ofall motor resistances (p0350, p0352, p0354). The temperature adaptation of the resistances is not taken intoaccount.* only applies for VECTOR (r0107).Description: Displays the stator leakage time constant quadrature to the rotor direction (q axis).Note: The value is calculated from the total of all leakage inductances (p0233, p0356, p0359) divided by the total of allmotor resistances (p0350, p0352, p0355).The temperature adaptation of the resistances is not taken into account.Description: Sets the rated no-load current (I_F0) for the excitation.Description: Setting the rated current (I_F) of the controlled excitation rectifier (DC master).Description: Sets the starting point of the current-dependent current controller adaptation where the current controller gain p1715is effective.r0386[0...n] Motor stator leakage time constant / Mot T_stator leakVECTOR_G Can be changed: - Calculated: - Access level: 4Data type: FloatingPoint32 Dyn. index: MDS, p0130 Func. diagram: -P-Group: Motor Units group: - Unit selection: -Not for motor type: - Scaling: - Expert list: 1Min Max Factory setting- [ms] - [ms] - [ms]r0387[0...n] Motor stator leakage time constant q axis / Mot T_Sleak /T_SqVECTOR_G Can be changed: - Calculated: - Access level: 4Data type: FloatingPoint32 Dyn. index: MDS, p0130 Func. diagram: -P-Group: Motor Units group: - Unit selection: -Not for motor type: ASM, REL, FEM Scaling: - Expert list: 1Min Max Factory setting- [ms] - [ms] - [ms]p0389[0...n] Excitation rated no-load current / Exc I_noload_ratedVECTOR_G Can be changed: C2(1, 3) Calculated: - Access level: 1Data type: FloatingPoint32 Dyn. index: MDS, p0130 Func. diagram: 6727P-Group: Motor Units group: - Unit selection: -Not for motor type: ASM, PEM, REL Scaling: - Expert list: 1Min Max Factory setting0.00 [A] 10000.00 [A] 0.00 [A]p0390[0...n] Rated excitation current / Exc I_ratedVECTOR_G Can be changed: C2(1, 3) Calculated: - Access level: 1Data type: FloatingPoint32 Dyn. index: MDS, p0130 Func. diagram: 6727P-Group: Motor Units group: - Unit selection: -Not for motor type: ASM, PEM, REL Scaling: - Expert list: 1Min Max Factory setting0.00 [A] 10000.00 [A] 0.00 [A]p0391[0...n] Current controller adaptation starting point KP / I_adapt pt KPVECTOR_G Can be changed: C2(3), U, T Calculated: CALC_MOD_REG Access level: 3Data type: FloatingPoint32 Dyn. index: MDS, p0130 Func. diagram: 6714P-Group: Motor Units group: - Unit selection: -Not for motor type: REL Scaling: - Expert list: 1Min Max Factory setting0.00 [Arms] 6000.00 [Arms] 0.00 [Arms]