4 Faults and alarms4.2 List of faults and alarmsSINAMICS G130/G1501488 List Manual (LH2), 04/2014, A5E03263479AF07840 Drive: Infeed operation missingMessage value: -Message class: Infeed faulted (13)Drive object: VECTOR_GReaction: OFF2 (NONE)Acknowledge: IMMEDIATELYCause: The signal "infeed operation" is not present although the enable signals for the drive have been present for longerthan the parameterized monitoring time (p0857).- infeed not operational.- interconnection of the binector input for the ready signal is either incorrect or missing (p0864).- infeed is presently carrying out a line supply identification routine.Remedy: - bring the infeed into an operational state.- check the interconnection of the binector input for the signal "infeed operation" (p0864).- increase the monitoring time (p0857).- wait until the infeed has completed the line supply identification routine.See also: p0857 (Power unit monitoring time), p0864 (Infeed operation)F07841 (A) Drive: Infeed operation withdrawnMessage value: -Message class: Infeed faulted (13)Drive object: VECTOR_GReaction: OFF2 (NONE, OFF1, OFF3)Acknowledge: IMMEDIATELYCause: The signal "infeed operation" was withdrawn in operation.- interconnection of the binector input for the signal "infeed operation" is either incorrect or missing (p0864).- the enable signals of the infeed were disabled.- due to a fault, the infeed withdraws the signal "infeed operation".Remedy: - check the interconnection of the binector input for the "infeed operation" signal (p0864).- check the enable signals of the infeed and if required, enable.- remove and acknowledge an infeed fault.Note:If this drive is intended to back up the DC link regeneratively, then the fault response must be parameterized forNONE, OFF1 or OFF3. so that the drive can continue to operate even after the infeed fails.Reaction upon A: NONEAcknowl. upon A: NONEA07850 (F) External alarm 1Message value: -Message class: External measured value / signal state outside the permissible range (16)Drive object: All objectsReaction: NONEAcknowledge: NONECause: The condition for "External alarm 1" is satisfied.Note:The "External alarm 1" is initiated by a 1/0 edge via binector input p2112.See also: p2112 (External alarm 1)Remedy: Eliminate the causes of this alarm.Reaction upon F: Vector: NONE (IASC/DCBRK, OFF1, OFF2, OFF3, STOP2)Infeed: NONE (OFF1, OFF2)Acknowl. upon F: IMMEDIATELY (POWER ON)