D. Control Display Mode ( )Press the <>> key to select the screen.Screen 1-1]1]COPYRIGHT © 1997 CANON INC. CANON NP6045 REV. 1 MAR. 1997 PRINTED IN JAPAN (IMPRIME AU JAPON)CHAPTER 10 TROUBLESHOOTING10-142ItemFTMPRTMPRHUMLMP1LMP2WIREPLMTLLMTDescriptionIndicates the surface temperature of the fixing roller.(output of the main thermistor TH1)Indicates the machine internal temperature. (output ofthe thermal sensor on the DC controller PCB)Indicates the machine internal humidity. (output of thehumidity sensor on the DC controller PCB)Indicates the ON voltage of the scanning lamp(100/120V model)Indicates the ON voltage of the scanning lamp. (230Vmodel)Indicates a value other than '0' if the primary, pre-transfer, or transfer/separation charging wire cleanerstops at a point not its home position. Executing wiringcleaning for the appropriate wire in user mode willreturn the wire cleaner to its home position.Indicates '1' when the current value reaches the upperlimit or the lower limit during current control on theprimary charging assembly.Indicates '1' when the ON voltage of the scanninglamp reaches '1' and '2' if it reaches the lower limit.RemarksUnit: ÞCUnit: VUnit: V1: Error0: Normal0: Normal1: Error2: Error1/9