3. Adjusting the Tension of the Scanner CableBe sure to perform the following whenever you have installed the scanner cable.1) Remove the two mounting screws, and remove the left cover.2) Loosen the fixing screw on the tension spring bracket.3) Turn the tension adjusting screw so that the value is as indicated:• Turn the tension adjusting screw A so that the reading of the spring gauge is200 ±50 g when the middle of the scanner cable is pulled about 10 mm.Figure 10-2104. Adjusting the Mirror Position1. Routing the Scanner Drive Cable and Adjusting the Mirror PositionBe sure to perform the following whenever you have installed the scanner drive wire:1) Move the No. 1 mirror mount and the No. 2/No. 3 mirror mount to the left.2) Set the mirror positioning tool (front, rear; FY9-3011) as shown:Figure 10-211Figure 10-212AA10 mm10 mm(rear)(front)Mirror mountCOPYRIGHT © 1997 CANON INC. CANON NP6045 REV. 1 MAR. 1997 PRINTED IN JAPAN (IMPRIME AU JAPON)CHAPTER 10 TROUBLESHOOTING10-12