4. Potential Control System Conversion TableCOPYRIGHT © 1997 CANON INC. CANON NP6045 REV. 1 MAR. 1997 PRINTED IN JAPAN (IMPRIME AU JAPON)CHAPTER 10 TROUBLESHOOTING10-41Control (V)3.003.053.103.153.203.253.303.353.403.453.503.553.603.653.703.753.803.853.903.954.004.054.104.154.204.254.304.354.404.454.504.554.60Primary (μA)1,4001,3911,3821,3731,3651,3561,3471,3381,3301,3211,3121,3031,2951,2861,2771,2681,2601,2511,2421,2331,2251,2161,2071,1981,1901,1811,1721,1631,1551,1461,1371,1281,120Developing bias (V)037111518222630333741454852566063677175788286909397101105108112116120Pre-transfer (μA)0-2-4-6-8-10-12-14-16-18-20-22-24-26-28-30-33-35-37-39-41-43-45-47-49-51-53-55-57-59-61-63-66Transfer (μA)440437434431429426423420418415412409407404401398396393390387385382379376374371368365363360357354352Separation (μA)10096928885817773706662585551474340363228252117131062-1-5-8-12-16-20