2. Removing the Holding Tray Assembly from the Copier1) Open the front cover.2) Remove the fixing/pre-feeding cover.3) Slide out the holding tray assembly to the front and out of the copier.3. Removing the Holding Tray Re-Pick Up Assembly1) Slide out the holding tray assembly to the front and out of the copier.2) Remove the screw e (1 each), and remove the inlet assembly front upper cover qand the inlet assembly rear cover w; then, remove the two screws t and disconnectthe two connectors y to remove the side guide plate r.Figure 5-8653) Remove the three mounting screws u (front).Figure 5-866 (front)uuq wertyCOPYRIGHT © 1997 CANON INC. CANON NP6045 REV. 1 MAR. 1997 PRINTED IN JAPAN (IMPRIME AU JAPON)CHAPTER 5 PICK-UP/FEEDING SYSTEM5-87