14. Removing the Upper Separation Claw1) Slide out the fixing/feeding unit from the copier.2) Open the fixing delivery assembly, and release the spring q; then, remove the upperseparation claw w.Figure 6-22815. Adjusting the Nip (tightening the pressure adjusting nut)The nip width is correct if it is as indicated in Table 6-201. Otherwise, turn thepressure adjusting nut.Figure 6-229a and c are points 10 mm from either end of the copy paper.Table 6-201PaperfeedingdirectioncaA3 paperCenter ofpaperbq wCOPYRIGHT © 1997 CANON INC. CANON NP6045 REV. 1 MAR. 1997 PRINTED IN JAPAN (IMPRIME AU JAPON)CHAPTER 6 FIXING SYSTEM6-30Note:Dimensionsb| a – c |Measured when the upper andlower rollers are sufficiently heated.7.3 ± 0.5 mm0.5 mm or less