|
– 154 –Chapter 10 Specifications — Specifications terminal This is the LTC (linear time code) input terminalf Connector: BNCf Impedance: 1 kΩf Level: 1 to 2 V [p-p]Video delay time 1 line (H) When the frame synchronizer is set to [Off], and the up-converter is set to [Off]1 frame (F) When the frame synchronizer is set to on, or the up-converter is set to [On]f When the signals have passed through PinP, DVE, MultiView, down-converter, or DVI-IN, a maximum delay of 1 frame isapplied in each case.Control terminal terminal Compatible with 100Base-TX and AUTO-MDIX (For IP control)f Connection cable: LAN cable (CAT5E), max. 100 m (328 ft), STP (Shielded Twisted Pair) cable recommendedf Connector: RJ-45 terminal Compatible with 100Base-TX and AUTO-MDIX (For Control Panel AV-HS60C1/AV-HS60C2 connection)f Connection cable (supplied with AV-HS60C1/AV-HS60C2): LAN cable (CAT5E), straight cable, STP (Shielded TwistedPair), 10 m (32.8 ft)f Connector: RJ-45//(M)> terminalsRS-422 control terminalFor master connection for controlling external devicesf Connector: D-sub 9-pin (female) ×3, inch screw terminal RS-422 control terminalFor master/slave connection for controlling external devicesf Connector: D-sub 9-pin (female), inch screwf Switchable between master connection and slave connection by the menu terminal GPI IN: 18 inputs, general-purpose, photocoupler sensingALARM OUT: 1 output, open collector output (negative logic)f Connector: D-sub 25-pin (female), inch screw/terminalsGPI OUT: 48 outputs, selected from general purpose, tallyOpen collector outputf Connector: D-sub 25-pin (female) ×2, inch screw@@ NOTEt Use with the same segment is recommended for the devices which are connected to the unit. If the unit is connected to the devices whose segmentsare different, events dependent upon the settings inherent to the network equipment, for instance, may occur. Thoroughly check the connections withthe devices to which the unit will be connected prior to the start of operation.OtherAmbient operating temperature 0°C to 40°C (32°F to 104°F)Humidity 10% to 90% (no condensation)Dimensions (W×H×D) 482 mm×132 mm×418 mm (18-31/32 inches×5-3/16 inches×16-15/32 inches) (excluding protrusions)3RUMass AV-HS60U1: Approx. 12.6 k] (27.8 lbs.) (excluding accessories)AV-HS60U2: Approx. 13.5 k] (29.7 lbs.) (excluding accessories)r For AV‑HS60U1E/AV‑HS60U2EInrush current, measured according to European standard EN55103-1, on initial switch-on: 3 A, after a supply interruption of 5 s: 35 A (Each mainsinput)
PreviousNext |