– 140 –Chapter 8 System Menu — Maintenance settingsr Display details[No Alarm] Shows that there are no problems.[Alarm] Shows that there is a problem.[−]Not a target for determination.f When a power supply unit is not mountedf When [Off] is selected in each item of [Alarm Enable]Enabling/disabling the alarm display1 Select the button → [MAINTENANCE] → [Alarm] tab.2 Select an item in the [Alarm Enable] column below each [Main frame]/[Main Panel]/[Sub Panel1]/[Sub Panel2] column.f The [Sub Panel1]/[Sub Panel2] columns will be available in V2.00.00 or higher.[On] Alarm detection is enabled.[Off] Alarm detection is disabled.Log file recordingEach type of information in this unit such as alarms, are recorded in the built‑in log file.The log file can be saved to a memory card.1 Select the button → [MAINTENANCE] → [Alarm] tab.2 Select an item in [Log File] in the [Log] column.f Select the file to be loaded from the file selection screen.3 Select [OK].f Save the log file to a memory card.Startup settings/initializationStartup settingsSet the status replicated when the power is turned on.f The setting is fixed with [Resume Data] in the version below V2.00.00.1 Select the button → [MAINTENANCE] → [Boot] tab.2 Select [Resume Data] or [Project Data] in the [Boot Select] columnf Select the startup setting data.[Resume Data] Selects the resume data. When power is turned on, the system starts using the settings from the previous power-off.[Project Data]* Selects the project data. When power is turned on, the project file specified in the step 3 onwards is loaded.* This function will be available in V2.00.00 or higher.3 Select an item in [From] in the [Project Data] column.f Specify the storage location of the project file used during startup.[SD] Specify the memory card.[SSD] Specify the SSD.4 Select an item in [Project] in the [Project Data] column.f Specify the project file.Initializing the setting dataThe setting data can be reset to factory settings.1 Select the button → [MAINTENANCE] → [Boot] tab.2 Select an item in the [Initial] column.f Select the mode to be initialized.[Initial] Data is initialized except plug-in software and network setting values.[with Plugin]* Data is initialized including plug-in software.f Network setting values are not initialized.[with Plugin/NW] Data is initialized including plug-in software and network setting values.* This function will be available in V2.00.00 or higher.3 Select [OK] in the confirmation screen.f Initialize the settings data.