02/20004-27DocuPrint N2125 REP 3.12Repair-AdjustmentInitial IssueREP 3.12 Size Sensor ActuatorsParts List on PL 9.1RemovalWARNINGSwitch off the power and disconnect the Power Cord.1. Remove Tray 1.2. Remove the Left Interface Cover (REP 1.1).3. Remove Left Cover (REP 1.2).4. Remove the Front Cover Assembly (REP 1.6).5. Remove the Left Front Cover Assembly (REP 1.7).6. Remove Top Cover Assembly (REP 1.4).7. Remove the Left Plate Assembly (REP 1.11).8. Remove the Plate Handle (REP 1.12).9. Remove the Size Sensor Housing (REP 3.11).NOTE: Observe orientation of switch actuators before removal.10. Remove the four screws that secure the Size Sensor Actuators to the Size Sensor Hous-ing (Figure 1).11. From the back side, disengage the two Locking Tabs that secure the Size Sensor Actua-tors to the Housing Assembly and remove (Figure 1).Figure 1 Size Sensor ActuatorsReplacementRefer to inset (A)1. Position the Size Sensor Actuators below the Housing Assembly as shown.2. Press and hold (B) to allow the actuators (C) to fall into position.3. During reassembly ensure that locking tabs slide into position.4. Reinstall the components in the reverse order.