4) Turn the flat-blade screwdriver in the direction of arrow e to open the electrode platein the direction of arrow r, and remove the scanning lamp t.Figure 4-3021. If the scanning lamp is hot, wait until it has cooled.2. Do not leave fingerprints on the scanning lamp.3. If the surface of the scanning lamp is soiled, dry wipe it.2. Orientation of the Scanning LampOrient the scanning lamp q so that the protrusion in its middle points in the directionof the arrow (direction in which the mirror mount moves in reverse); for lengthwiseorientation, keep the logo mark facing the front.Figure 4-303When installing the scanning lamp, avoid touching its surface.4-26CHAPTER 4 IMAGE FORMATION SYSTEMCOPYRIGHT © 1997 CANON INC. CANON NP6330 REV.0 MAY 1997 PRINTED IN JAPAN (IMPRIME AU JAPON)ertqMirror mount reverse directionNote:Note: