August 20072-786 WorkCentre 5687 FamilyOF8, OF9Status Indicator RAPsFigure 2 Tray 3 feed assemblyOF9 False Fuser End of Life RAPUse this RAP if the fuser module has reached its end of life prematurely.Initial ActionsEnter the machine status / supplies and check the fuser module image count. If the imagecount is unexpectedly high, 422,000 or greater, then the CRUM data is corrupted.ProcedureCheck the following:• Refer to Wiring Diagram 4 and the wiring harness at PJ 141.• Check that the wires from the vacuum transport fan have not been trapped in the fuserCRUM socket, Figure 1. Repair the wiring or install a new short paper path assembly, PL10.25 Item 1. Use a cable tie to route the wires away from the fuser module.• Check for damage to the fuser CRUM socket on the drives module, (32-55 ppm) PL 4.15Item 1, (65-87 ppm) PL 4.10 Item 1.• Check for damage to the CRUM plug on the fuser module, (32-55 ppm) PL 10.8 Item 1,(65-87 ppm) PL 10.10 Item 1.• Go to OF10 Intermittent Failure RAP and refer to the Electrostatic Discharge Checkout.Remove the spacers