August 20072-678 WorkCentre 5687 Family14-320, 14-322Status Indicator RAPs14-320 CVT Active Hot Line in Wrong State RAP14-320 The CVT active hot line (DADH) is in the wrong state before a scan calibration or scan.ProcedureSwitch off the machine, then switch on the machine, GP 14. The fault code is still present.Y NPerform SCP 6 Final Actions.Check the leads and the connections that follow:• (32-55 ppm) Check between PJ 188 pin 5 on the DADH PWB and PJ 102 pin 1 on theImage processing PWB. Refer to Wiring Diagram 8.• (65-87 ppm) Check between PJ 188 pin 5 on the DADH PWB and PJ 102 pin 1 on theImage processing PWB. Refer to Wiring Diagram 9.14-322 Platen Active Hot Line in Wrong State RAP14-322 The platen active hot line is in the wrong state before a scan calibration or scan.ProcedureSwitch off the machine, then switch on the machine, GP 14. The fault code is still present.Y NPerform SCP 6 Final Actions.Check the leads and the connections that follow:• (32-55 ppm) Check between PJ 452 pin 5 and pin 6 on the scanner PWB and PJ451 pin13 and pin 14 on the CCD PWB. Refer to Wiring Diagram 31.• (65-87 ppm) Check between PJ 125 pin 5 and pin 6 on the scanner PWB and PJ226 pin5 and pin 6 on the Image processing PWB. Refer to Wiring Diagram 9.