August 20072-729WorkCentre 5687 Family 22-761, 22-774Status Indicator RAPs22-761 IQA Factor Set to Minimum RAP22-761 The (IQA) image quality adjustment factor has been set to the minimum value (light).The fault will occur if the test pattern is dark, but not dark enough to create a 22-451 fault. Thismay result in subsequent image quality being too light, as the ROS output level may be toolow. Check in fault history to find a 22-761 failure.Initial ActionsLoad A4 (8.5x11 inch) white paper LEF in the Bypass Tray.ProcedurePerform the following:• Make print samples and if the images are dark or black refer to the IQ1 Image QualityEntry RAP to resolve image quality defects for dark or black images.• Check that the image quality adjustment factor in the NVM is not too high causing highROS light level output and very dark test pattern.Enter dC131 location 06-04 (IQA) image quality adjustment factor and reset value to 100.Reboot the machine and repeat the ADJ 9.2 Image Quality Adjustment Routine.• Check in dC131 location 06-01 ROS light level, is correct and not set high. Enter dC131location 06-01 ROS light level and reset value to default. Reboot the machine and repeatthe ADJ 9.2 Image Quality Adjustment Routine.• Check that the developer bias is not set high. Enter dC131 location 09-021 developer biasprint level and reset value to default.• If the fault still occurs the ROS output level may be too high. Go to the RAP 03-395, 396,852, 853 IOT PWB Fault RAP.22-774 CPSR File Cabinet Enable Failure RAP22-774 The system manager failed to enable the CPSR file cabinet option.ProcedurePerform the following:• Switch off the machine, then switch on the machine, GP 14.• To enable the option perform the following:1. Press the (Access) button to enter the Tools pathway.2. On the key pad enter (1111) or the current password and select Enter.3. Select Go to Tools.4. Wait for the screen to refresh and select More.5. Select Optional Services.6. Select the CPSR File Cabinet.7. Select Enable.8. Select Save9. Select Exit Tools10. The network controller, if fitted, will reset with the new configuration. When completethe optional feature removed will not appear in the machine user interface screen.