August 20072-229WorkCentre 5687 Family 08-174, 08-181Status Indicator RAPs08-174 Missing Pre-release Sheet RAP08-174 The IOT detected a missing pre-release sheet.Initial Actions• Enter the machine status mode and check for the active messages. Refer to OF4 StatusCodes and Message RAP for the jam clearance procedure.• Check the condition of the paper in all trays. Refer to IQ1 and GP 20.• Check for obstructions in the registration paper path.• Make sure that all covers and paper guides are closed, and latch correctly.ProcedureIf the initial actions did not resolve the problem. Switch off the machine, then switch on themachine, GP 14. If a fault code is displayed then go to the appropriate RAP.08-181 Unexpected Time Out in Simplex Inverted ModeRAP08-181 The IOT detected an unexpected time out for a known simplex inverted sheet of paper.Initial Actions• Enter the machine status mode and check for the active messages. Refer to OF4 StatusCodes and Message RAP for the jam clearance procedure.• Check the condition of the paper in all trays. Refer to IQ1 and GP 20.• Check for obstructions in the simplex and inverted paper path.• Make sure that all covers and paper guides are closed, and latch correctly.ProcedureIf the initial actions did not correct the problem, perform the following:• Switch off the machine, then switch on the machine, GP 14.• If a fault code is displayed then go to the appropriate RAP.• Check the inverter gate is free to move and operates correctly, PL 10.12 Item 7.