2-27Phaser 3635MFP 08-610, 08-700Status Indicator RAPsDraft 408-610 Duplex Jam 1 RAP08-610 The lead edge of the document failed to actuate the registration sensor after the duplexjam 1 sensor within the correct time.ProcedureWARNINGSwitch off the electricity to the machine. Disconnect the power cord from the customersupply while performing tasks that do not need electricity. Electricity can cause death orinjury. Moving parts can cause injury.NOTE: The front cover assembly interlock switch must be closed to supply +24V to the motorsand clutches.Refer to Wiring Diagram 2 and Wiring Diagram 9. Perform the following:1. Open the rear cover assembly, PL 8.20 Item 11. Remove the duplex assembly, PL 10.23Item 18, then remove all jammed paper.2. Check the paper path for damage or obstructions.3. Check that the registration sensor actuator, PL 8.25 Item 14 moves freely and is not dam-aged. If necessary, install a new registration sensor actuator, PL 8.25 Item 14.4. Enter dC330 code 08-500. Check the registration sensor (Q08-500). If necessary, install anew HVPS, PL 1.10 Item 3.NOTE: The registration sensor is mounted on the HVPS.5. Enter dC330 code 04-300 to run the duplex motor (MOT04-300), PL 10.20 Item 1. Checkthat the duplex drive gear, PL 10.20 Item 12 rotates.6. Check the wiring between the duplex motor and CN7 on the Connection PWB. Install newcomponents as necessary, PL 10.20 Item 12, PL 3.10 Item 17.7. Manually rotate the duplex drive belt, PL 10.23 Item 12. Check that the duplex drive rolls,PL 10.23 Item 13, PL 10.23 Item 14 are clean and rotate freely. Install new componentsas necessary, PL 10.23.8. Install new components as necessary:• Duplex assembly, PL 10.23 Item 18.• Bypass feed assembly, PL 7.10 Item 29.• Connection PWB, PL 3.10 Item 17.08-700 Out Bin Full RAP08-700 The machine has detected that the exit tray is full.ProcedureWARNINGSwitch off the electricity to the machine. Disconnect the power cord from the customersupply while performing tasks that do not need electricity. Electricity can cause death orinjury. Moving parts can cause injury.Refer to Wiring Diagram 3. Perform the following:1. Remove all documents from the exit tray. Check that the out bin full sensor actuator, PL10.30 Item 4 moves freely and is not damaged.2. Enter dC330 code 08-720. Check the out bin full sensor (Q08-720), PL 10.30 Item 2.3. Check the wiring between the out bin full sensor and CN2 on the Main PWB. If necessary,install a new out bin full sensor, PL 10.30 Item 2.4. Enter dC330 code 04-200. Check that the exit motor (MOT04-200), PL 10.20 Item 4, runsand drives the exit roll, PL 10.25 Item 22.5. Check the wiring between the exit motor and CN2 on the Connection PWB. Install newcomponents as necessary, PL 10.25 Item 22, PL 3.10 Item 17.6. If necessary install a new exit cover assembly, PL 10.30 Item 12.