6-31Phaser 3635MFP dC001, dC109General Procedures and InformationDraft 4dC001 Reset Auditron Master PINPurposeTo reset the Auditron and the System Administration password to the default, (1111).NOTE: The Auditron and the System Administration password is the same item.Procedure1. Enter diagnostics, GP 1.2. Select Diagnostic Routines, then select Other Routines, then select 001 ResetAuditron Master PIN.3. Select Reset Auditron Master PIN.4. Select confirm or cancel.dC109 Embedded Fax Protocol ReportPurposeThis procedure allows the CSE to print out the Fax protocol report. The protocol report containsthe protocol information about the last fax transmissions. The protocol report contains the fol-lowing:• Date and time.• The Fax number and Fax name.• Machine firmware versions.• The communication summary with the time and a FCF column. The FCF column will dis-play abbreviations, refer to Table 1.Procedure1. Enter diagnostics, GP 1.2. Select Diagnostic Routines.3. Select Fax dC Routines, then select 109 Protocol Report.4. Select Print.5. The Print Report button greys out until the job has been submitted. The Fax card buildsthe protocol report job and places the job in the Fax NVM. This is the equivalent of anactive Fax job in the Fax card queue.6. The protocol report prints out.Analyse the Fax Protocol Report.For an example of a Fax protocol report, refer to Figure 1.• The time column records the time at which each event occurs, from the start of the com-munication.• The S/R column shows if the Fax job was sent or received.• The FCF data column contains information regarding the type of information beingexchanged.• The FIF column providing a Hex value of the data information contained in the G3 facsim-ile information field.If the protocol report shows a fault and go to the 20-100 to 20-900 Fax Faults RAP. if the proto-col report does not show a fault, go to the 20A Fax Faults Without a Code RAP.