2-3Phaser 3635MFP 01-100, 01-110Status Indicator RAPsDraft 401-100 Door Open RAP01-100 The machine has detected that the front door is open. When the front door is openthere is no +24V supply to the motors or the HVPS.ProcedureWARNINGSwitch off the electricity to the machine. Disconnect the power cord from the customersupply while performing tasks that do not need electricity. Electricity can cause death orinjury. Moving parts can cause injury.Refer to Wiring Diagram 2. Perform the following:1. Switch off the machine, then switch on the machine.2. Check that the interlock switch actuator on the front cover assembly, PL 28.10 Item 7 isnot missing or damaged. If necessary, install a new front cover assembly.3. Check that the front cover assembly closes correctly.4. If necessary, install a new HVPS, PL 1.10 Item 3.NOTE: The front door interlock switch is mounted on the HVPS.01-110 Fuser Door Open RAP01-110 The machine has detected that the fuser door is open. When the front door is openthere is no +24V supply to the motors or the HVPS.ProcedureWARNINGSwitch off the electricity to the machine. Disconnect the power cord from the customersupply while performing tasks that do not need electricity. Electricity can cause death orinjury. Moving parts can cause injury.Refer to Wiring Diagram 2. Perform the following:1. Switch off the machine, then switch on the machine.2. Open the rear door, then the fuser door, PL 10.12 Item 19.3. Check that the interlock switch actuator on the fuser door, PL 10.12 Item 19 is not missingor damaged. If necessary, install a new fuser door.4. Check that the fuser door assembly closes correctly.5. If necessary, install a new HVPS, PL 1.10 Item 3.NOTE: The fuser door interlock switch is mounted on the HVPS.