3-17Phaser 3635MFP IQ16, IQ17Image QualityDraft 44. Install new components as necessary.5. Check the condition of the fuser assembly. Install new components as necessary, PL10.10 to PL 10.15.6. Perform OF7 Main PWB Check RAP.IQ17 Periodic Printing Defects Check RAPUse this RAP when the printed image shows regular defects in black or white, across the pro-cess direction.ProcedureWARNINGSwitch off the electricity to the machine. Disconnect the power cord from the customersupply while performing tasks that do not need electricity. Electricity can cause death orinjury. Moving parts can cause injury.1. Clean the xerographic drum, make 10 blank copies. If necessary, install a new print car-tridge, PL 9.10 Item 1.2. Measure the distance between the repeated black or white abnormality. Refer to Table 1identify the possible cause.3. Install new components as necessary.4. If the defect appears to be fuser related, ensure that the paper tray settings match thepaper or media size in the trays. Also, ensure the media is within specification. Refer toGP 9 Paper and Media Specifications.Table 1 Defect distanceDefectdistanceKind of abnormalimage Roll Component Parts List Ref.95mm(3.7 inches)White spot. Black spot Xerographic drum Print cartridge PL 9.10 Item 138mm(1.5 inches)White spot. Black spot Charge roll Print cartridge PL 9.10 Item 145mm(1.8 inches)Horizontal dark band Supply roll Print cartridge PL 9.10 Item 147mm(1.9 inches)Black spot, White spot Transfer roll Transfer roll PL 9.10 Item 289mm(3.5 inches)Black spot, White spot Heat roll Fuser assembly PL 10.15 Item 151mm(2 inches)Back side contamination Pressure roll 1 Fuser assembly PL 10.15 Item 264mm(2,5 inches)Back side contamination Pressure roll 2 Fuser assembly PL 10.15 Item 3