4-31Phaser 3635MFP REP 10.1, REP 10.2Repairs and AdjustmentsDraft 4REP 10.1 Duplex MotorParts List on PL 10.20RemovalWARNINGSwitch off the electricity to the machine. Disconnect the power cord from the customersupply while performing tasks that do not need electricity. Electricity can cause death orinjury. Moving parts can cause injury.WARNINGTake care during this procedure. Sharp edges may be present that can cause injury.CAUTIONBefore performing this procedure, refer to General Disassembly Precautions, GP 10.1. Remove the right cover, REP 28.1.2. Remove the duplex drive assembly, PL 10.20 Item 13.3. Remove the duplex motor, PL 10.20 Item 1 from the drive assembly.Replacement1. Replacement is the reverse of the removal procedure.REP 10.2 Exit MotorParts List on PL 10.20RemovalWARNINGSwitch off the electricity to the machine. Disconnect the power cord from the customersupply while performing tasks that do not need electricity. Electricity can cause death orinjury. Moving parts can cause injury.WARNINGTake care during this procedure. Sharp edges may be present that can cause injury.CAUTIONBefore performing this procedure, refer to General Disassembly Precautions, GP 10.1. Remove the right cover, REP 28.1.2. Disconnect the harness from the exit motor, PL 10.20 Item 4.3. Remove the exit drive assembly, Figure 1.Figure 1 Exit drive assembly removal4. Remove 4 gears from the exit drive assembly to gain access to the motor mountingscrews, refer to PL 10.20.5. Remove 2 screws to remove the exit motor from the exit motor bracket.Replacement1. Replacement is the reverse of the removal procedure.1Remove 3 screws, then theexit drive assembly.