4-34 Phaser 3635MFPREP 10.5, REP 10.6Draft 4Repairs and AdjustmentsREP 10.5 Fuser TerminalParts List on PL 10.25RemovalWARNINGSwitch off the electricity to the machine. Disconnect the power cord from the customersupply while performing tasks that do not need electricity. Electricity can cause death orinjury. Moving parts can cause injury.CAUTIONBefore performing this procedure, refer to General Disassembly Precautions, GP 10.1. Remove the DADF PL 5.10.2. Remove the scanner REP 14.1.3. Remove the rear cover and the left and right covers REP 28.1.4. Remove the outbin REP 28.2.5. Remove the LSU REP 6.1.6. Disconnect CON2 from the SMPS, REP 1.1.7. Disconnect CN19 from the Main PWB.8. Remove the fuser terminal, PL 10.25 Item 8.9. Disconnect the red and black harness from the fuser terminal.Replacement1. Replacement is the reverse of the removal procedure.REP 10.6 Heat LampParts List on PL 10.15RemovalWARNINGSwitch off the electricity to the machine. Disconnect the power cord from the customersupply while performing tasks that do not need electricity. Electricity can cause death orinjury. Moving parts can cause injury.CAUTIONBefore performing this procedure, refer to General Disassembly Precautions, GP 10.1. Remove the fuser assembly PL 10.10.2. Remove the left and right lamp caps, PL 10.12 Item 2 and PL 10.12 Item 3.3. Disconnect the harnesses from the heat lamp, Figure 1 and Figure 3.Figure 1 Right harness disconnection1Disconnect the harness at the right end.2Remove the fixing screw.