E6581611L-11212. Specifications12.1 Models and their standard specifications Standard specificationsItem SpecificationInput voltage 3-phase 240VApplicable motor (kW) 0.4 0.75 1.5 2.2 4.0 5.5 7.5 11 15Type VFS15Form 2004PM-W 2007PM-W 2015PM-W 2022PM-W 2037PM-W 2055PM-W 2075PM-W 2110PM-W 2150PM-WCapacity (kVA) Note 1) 1.3 1.8 3.0 4.2 6.7 10.5 12.6 20.6 25.1Rated output/current(A) Note 2)3.3(3.3)4.8(4.4)8.0(7.9)11.0(10.0)17.5(16.4)27.5(25.0)33.0(33.0)54.0(49.0)66.0(60.0)Output voltage Note 3) 3-phase 200V to 240VRatingOverload current rating 150%-60 seconds, 200%-0.5 secondVoltage-frequency 3-phase 200V to 240V - 50/60HzAllowable fluctuation Voltage 170V to 264V Note 4), frequency ±5%Power supplyRequired Power supplycapacity (kVA) Note 5) 1.4 2.5 4.3 5.7 9.2 13.8 17.8 24.3 31.6Protection degree (IEC60529) IP20Cooling method Self-cooling Forced air-cooledColor RAL7016Built-in filter Basic filterItem SpecificationInput voltage 1-phase 240V 3-phase 500VApplicable motor (kW) 0.2 0.4 0.75 1.5 2.2 0.4 0.75 1.5 2.2 4.0 5.5 7.5 11 15Type VFS15S VFS15Form 2002PL-W2004PL-W2007PL-W2015PL-W2022PL-W4004PL-W4007PL-W4015PL-W4022PL-W4037PL-W4055PL-W4075PL-W4110PL-W4150PL-WCapacity (kVA) Note 1) 0.6 1.3 1.8 3.0 4.2 1.1 1.8 3.1 4.2 7.2 10.9 13.0 21.1 25.1Rated output current(A) Note 2)1.5(1.5)3.3(3.3)4.8(4.4)8.0(7.9)11.0(10.0)1.5(1.5)2.3(2.1)4.1(3.7)5.5(5.0)9.5(8.6)14.3(13.0)17.0(17.0)27.7(25.0)33.0(30.0)Rated output voltage Note 3) 3-phase 200V to 240V 3-phase 380V to 500VRatingOverload current rating 150%-60 seconds, 200%-0.5 second 150%-60 seconds, 200% -0.5 secondVoltage-current 1-phase 200V to 240V – 50/60Hz 3-phase 380V to 500V - 50/60HzAllowable fluctuation Voltage 170V to 264V Note 4),frequency±5% Voltage 323V to 550V Note 4), frequency ±5%Power supplyRequired Power supplycapacity (kVA) Note 5) 0.8 1.4 2.3 4.0 5.4 1.6 2.7 4.7 6.4 10.0 15.2 19.5 26.9 34.9Protection degree (IEC60529) IP20 IP20Cooling method Self-cooling Forced air-cooled Forced air-cooledColor RAL7016 RAL7016Built-in filter EMC filter EMC filterNote 1. Capacity is calculated at 220V for the 240V models, at 440V for the 500V models.Note 2. Indicates rated output current setting when the PWM carrier frequency (parameter f300) is 4kHz or less. Whenexceeding 4kHz, the rated output current setting is indicated in the parentheses. It needs to be further reduced forPWM carrier frequencies above 12 kHz.The rated output current is reduced even further for 500V models with a supply voltage of 480V or more.The default setting of the PWM carrier frequency is 12kHz.Note 3. Maximum output voltage is the same as the input voltage.Note 4. At 180V-264V for the 240V models, at 342V-550V for the 500V models when the inverter is used continuously (load of100%).