E6581611K-381111.8 Application easy settingWhen 1 to 7 is set by parameter aua (Application easy setting), the parameters of the table below are set toparameter f751 to f782 (Easy setting mode parameter 1 to 32).Parameter f751 to f782 are displayed at easy setting mode.Refer to section 4.2 about easy setting mode.aua 1: Initial easysetting2:Conveyor3: Materialhandling 4: Hoisting 5: Fan 6: Pump 7:Compressorf751 cmod cmod cmod cmod cmod cmod cmodf752 fmod fmod fmod fmod fmod fmod fmodf753 acc acc acc acc acc acc accf754 dec dec dec dec dec dec decf755 ul ul ul ul fh fh fhf756 ll ll ll ll ul ul ulf757 thr thr thr thr ll ll llf758 fm fm fm fm thr thr thrf759 - pt pt pt fm fm fmf760 - olm olm olm pt pt ptf761 - sr1 sr1 f304 f201 f201 f216f762 - sr2 sr2 f308 f202 f202 f217f763 - sr3 sr3 f309 f203 f203 f218f764 - sr4 sr4 f328 f204 f204 f219f765 - sr5 sr5 f329 f207 f207 fpidf766 - sr6 sr6 f330 f216 f216 f359f767 - sr7 sr7 f331 f217 f217 f360f768 - f201 f240 f332 f218 f218 f361f769 - f202 f243 f333 f219 f219 f362f770 - f203 f250 f334 f295 f295 f363f771 - f204 f251 f340 f301 f301 f366f772 - f240 f252 f341 f302 f302 f367f773 - f243 f304 f345 f303 f303 f368f774 - f250 f308 f346 f633 f610 f369f775 - f251 f309 f347 f667 f611 f372f776 - f252 f502 f400 f668 f612 f373f777 - f304 f506 f405 - f633 f380f778 - f308 f507 f415 - f667 f389f779 - f309 f701 f417 - f668 f391f780 - f701 - f648 - - f621f781 f701 f702 - f701 - - -f782 psel psel psel psel psel psel psel