E6581611F-1286In this case, the output frequency displayed in standard monitor mode changes by 0.1 Hz, as usual.■ When f707 is not 0.00, and f708 is not 0The value displayed on the panel also can also be changed in steps.Output frequency displayed in standard monitor mode = Internal output frequency ×[Parameter setting]Title Function Adjustment range Default settingf707 Free step 1 (1-step rotation of settingdial)0.00: Automatic0.01-fh (Hz) 0.00f708 Free step 2 (panel display) 0: Automatic1-255 0■ Operation example 1f707 = 0.00 (disabled)By rotating the setting dial 1 step, the panel frequency command value changes only 0.1 Hz.When f707 = 10.00 (Hz) is setRotating the setting dial 1 step changes the panel frequency command value in 10.00 Hz increments, from0.00 up to 60.00 (Hz).■ Operation example 2When f707=1.00 (Hz), and f708=1:By rotating the setting dial 1 step, the frequency setting fc changes in steps of 1Hz: 0→ 1 → 2 → ... → 60(Hz) and also the value displayed on the operation panel changes in steps of 1. Use these settings to hidedecimal fractions and also the value displayed on the operation panel changes in steps of 1. Use thesesettings to hide decimal fractions.6.34.5 Select the initial display of the panelf710 : Initial panel display selectionf720 : Initial extension panel display selection• FunctionThis parameter specifies display format of the standard monitor mode when power is ON. Differentcontents can be displayed on the operation panel of main unit and the extension panel (option).■ Changing the display format while power is ONWhen the power is ON, the standard monitor mode displays the output frequency (default setting) such as"0.0" or "off". This format can be changed to any other monitor display format by setting f710.However, the initial letter including t or c will not be displayed. When the power is ON, set the display of theextension panel at f720., Different contents can be displayed on the operation panel of main unit and the extension panel (option).