E6581611F-1266.2 Selection of operation mode6.2.1 Selection of start/stop and frequency settings : Command mode selection : Frequency setting mode selection FunctionThese parameters are used to specify which input device (panel keypad, terminal block, orcommunication) takes priority in entering an operation stop command or frequency setting mode (terminalVIA/VIB/VIC, setting dial, communication, or UP/DOWN from external logic).[Parameter setting]Title Function Adjustment range Default setting Command mode selection0: Terminal block1: Panel keypad (including extension panel)2: RS485 communication3: CANopen communication4: Communication option1[Programmed value]: Terminal blockoperation ON and OFF of an external signal run and stop operation.: Panel keypadoperationPress the and keys on the panel keypad to run and stop.Operation can also be done from the extension panel.: RS485communicationRun/stop operations by RS485 communication from an external device.⇒ Refer to section 6.33.3: CANopencommunicationRun/stop operations by CANopen communication from an external device.⇒ Refer to “CANopen communication Instruction Manual E6581911”.4: CommunicationoptionRun/stop operations by commands from a communication option.⇒ Refer to each Instruction Manual of option.* Operation command selected by and the operation commands from the terminal block can beswitched alternately with ON/ OFF of input terminal. (input terminal function number 108, 109) See the table ofinput terminal function selection in section 11.6.* When priority is given to commands from a linked computer or terminal block, they have priority over thesetting of .STOPRUN