E6581611K-211 Basic parametersTitle CommunicationNo. Function UnitMinimumsetting unitPanel/CommunicationAdjustment range DefaultsettingUsersetting Reference 0003 Command modeselection- - 0: Terminal block1: Panel keypad (including extensionpanel)2: RS485 communication3: CANopen communication4: Communication option1 3.26.2.17.3 0004 Frequency settingmode selection 1- - 0: Setting dial 1(save even if power isoff)1: Terminal VIA2: Terminal VIB3: Setting dial 2(press in center tosave)4: RS485 communication5: UP/DOWN from external logicinput6: CANopen communication7: Communication option8: Terminal VIC9, 10: -11: Pulse train input12, 13: -14: sro0 3.26.2.16.10.15.87.3 0005 Meter selection - - 0: Output frequency1: Output current2: Frequency command value3: Input voltage (DC detection)4: Output voltage (command value)5: Input power6: Output power7: Torque8: -9: Motor cumulative load factor10: Inverter cumulative load factor11: PBR (Braking resistor) cumulativeload factor12: Stator frequency13: VIA input value14: VIB input value15: Fixed output 1(output current 100% equivalent)16: Fixed output 2(output current 50% equivalent)17: Fixed output 3(Other than the output current)18: RS485 communication data19: For adjustments ( set value isdisplayed.)20: VIC input value21: Pulse train input value22: -23: PID feedback value24: Integral input power25: Integral output power0 0006 Meter adjustmentgain- - - -5.1 0008 Forward/reverserun selection(Panel keypad)- - 0: Forward run1: Reverse run2: Forward run (F/R switching onextension panel)3: Reverse run (F/R switching onextension panel)0 6.2.2