E6581611F-136[Parameter setting]Title Function Adjustment range Default setting Frequency setting mode selection 10: Setting dial 1(save even if power is off)1: Terminal VIA2: Terminal VIB3: Setting dial 2(press in center to save)4: RS485 communication5: UP/DOWN from external logic input6: CANopen communication7: Communication option8: Terminal VIC9, 10: -11: Pulse train input12, 13: -14: sro0[Programmed value]: Setting dial 1Frequencies are set by rotating the setting dial on the inverter. Like the positionof notches in a volume knob, the frequency setting value at the position of thenotch is saved.⇒ Refer to section 3.2.2: Terminal VIAA frequency command is set by means of external analog signals.(VIA terminal: 0 –10Vdc)⇒ Refer to section 3.2.2 and 7.3: Terminal VIBA frequency command is set by means of external analog signals.(VIB terminal: 0 - +10Vdc or -10 - +10Vdc)⇒ Refer to section 3.2.2 and 7.3: Setting dial 2Frequencies are set by rotating the setting dial on the inverter. Press the centerof the setting dial to save the frequency setting value.⇒ Refer to section 3.2.2: RS485communicationFrequencies are set by RS485 communication from an external device.⇒ Refer to section 6.33: UP/DOWN fromexternal logic inputFrequencies are set by up/down commands from a terminal.⇒ Refer to section 6.6.3: CANopencommunicationFrequencies are set by CANopen communication from an external device.⇒ Refer to “CANopen communication Instruction Manual E6581911”.: CommunicationoptionFrequencies are set by commands from a communication option.⇒ Refer to each Instruction Manual of option.