E6581611G-97(3) Holding the output of signals in ON status, If the conditions for activating the functions assigned to RY-RC terminal and OUT terminal agree with andas a result the output of signals is put in ON status, the output of signals is held ON, even if the conditionschange. (Output terminal holding function)Assign function 80 to 83 to an input terminal.Once RY-RC terminal or OUT terminal is turned on when the assigned input terminal is ON, RY-RC terminalor OUT terminal is held ON.Function No. Code Function Action80 HDRY Holding of RY-RC terminaloutputON : Once turned on, RY-RC are held on.OFF: The status of RY-RC changes in realtime according to conditions.82 HDOUT Holding of OUT-NO terminaloutputON : Once turned on, OUT-NO are held on.OFF: The status of OUT-NO changes in realtime according to conditions.Each one of the following numbers (81, 83) is an inverse signal. Usage example ···operational signal, brake signalLow-speed detection signal outputs the signal when the output frequency exceeds the setting of f100.This signal can be used as an operation signal by setting f100 to 0.0Hz. (Default setting)This signal can also be used as an electromagnetic brake excitation/release signal.Setting example) When outputting the brake signal from RY-RC terminalTitle Function Adjustment range Example of settingf100 Low-speed signal output frequency 0.0 - fh (Hz) 2.5f130 Output terminal selection 1A (RY-RC) 0-255 4: LOW (Low-speeddetection signal)Output frequencyTime [s]Low-speed detection signal :RY-RC terminals ONOFFInversion of low-speeddetection signalONOFF[Hz]0Setting frequency