E6581611F-86Outputfrequency (Hz)DecelerationtimeAccelerationtimeLoad torque : smallThe moment of inertia : smallTime[sec]0Shorten acceleration/deceleration timeDecelerationtimeAccelerationtimeOutputfrequency (Hz)Time[sec]0Lengthen acceleration/deceleration timeLoad torque : largeThe moment of inertia : largeSet (automatic acceleration/deceleration) to or .[Parameter setting]Title Function Adjustment range Default setting Automatic acceleration/deceleration0: Disabled (manual setting)1: Automatic2: Automatic (only at acceleration)0, When automatically setting acceleration/deceleration time, always change the acceleration/decelerationtime so that it conforms to the load. For inverters that require a fixed acceleration/deceleration time, usethe manual settings (, )., Setting acceleration/deceleration time (, ) in conformance with mean load allows optimumsetting that conforms to further changes in load., Use this parameter after actually connecting the motor., When the inverter is used with a load that fluctuates considerably, it may fail to adjust the acceleration ordeceleration time in time, and therefore may be tripped., Do not set = when using a dynamic braking resistor (optional).[Methods of setting automatic acceleration/deceleration]Operation panelaction LED display OperationDisplays the output frequency.(When standard monitor display selection is set to [output frequency]) The first basic parameter “” (history function) is displayed. Turn the setting dial to the right to change the parameter to . Set values are displayed by pressing the center of the setting dial. Turn the setting dial to the right to switch 1 or . Press the center of the setting dial to save the changed set value. and the set value are displayed alternately., Assigning the fast stop command 2 (function number 122/ 123) to any logic input terminal, it can bechanged automatic deceleration by compulsion.MODE