S3F84B8_UM_REV 1.00 4 CONTROL REGISTERS4-304.1.30 PWMCCON — PWM CMP CONTROL REGISTER: F0H, BANK0Bit Identifier .7 .6 .5 .4 .3 .2 .1 .0RESET Value 0 0 0 0 0 0 0 0Read/Write R/W R/W R/W R/W R/W R/W R/W R/WCMP3 PWM Linkage Mode Selection BitsX 0 Disables linkage.0 1 Soft Lock.7–.61 1 Hard lockCMP2 PWM Linkage Mode Selection BitX 0 Disables linkage.0 1 Soft Lock.5–.41 1 Hard lockCMP1 PWM Lock Mode Selection BitX 0 Disables linkage.0 1 Soft Lock.3–.21 1 Hard lockCMP0 PWM Trigger Mode Selection BitX 0 Disables linkage.0 1 Normal trigger.1–.01 1 Delay triggerNOTE: When CMP-PWM linkage is used, PWMCCON must be set to appropriate value before enabling PWM.